PARKLEX FACADE - SPECIFICATIONS

Printer Friendly Version: Parklex Facade Product Specifications [25k]
Adobe Acrobat® Reader is required.
Get it here for free.

SECTION 07430   -  EXTERIOR GRADE WOOD COMPOSITE PANEL

PARKLEX FACADE

* NOTE TO SPECIFIER:
Distributed by:  Finland Color Plywood Corporation

Corporate Headquarters
1310 Main St.
Venice, CA 90291
Bus: (310) 396-9991
Bus Fax: (310) 396-4482
E-mail: info@fcpcusa.com
Warehouses in Los Angeles, CA & Port Newark, NJ
http://www.fcpcusa.com/


Manufactured by: Composites Gurea, S.A.

Zalain Auzoa 13
31780
Vera de Bidasoa, Navarra
Spain
http://www.parklex.com/

PARKLEX FACADE is a prefinished exterior grade wood composite panel. This HIGH QUALITY panel system has been treated with durable THERMO-HARDENED resins and has a bakelite core. The panel is dimensionally stable and is suitable for exterior applications. Minimum maintenance is required; clean with water and non-abrasive cleaner.  PARKLEX FAÇADE is highly resistant to varying climatic conditions, including freeze/thaw, salt spray, dry climate and UV ray exposure. It is non-toxic and resists mold, mildew, fungus and is impervious to termite.  Parklex Façade  In 2003, improvements to the Parklex Facade were put into production. The improvements increase the age resistance and dimensional stability of the panel. An additional layer of clear film, developed by the scientists at Parklex, greatly increase the UV resistance and color stability of the face veneer. Additionally, the surface gloss of the finish is retained, showing no sign of change during artificial ageing testing. The improvements also add increased protection against humidity absorption, increasing the dimensional stability of the panel.

PART 1  - GENERAL

1.1       WORK

A.  Provide everything required to complete the work as shown on the Drawings and specified herein.

1.2       QUALITY STANDARDS

A.  Provide experienced, well-trained workers competent to complete the work as specified.  Fabricator/installer shall be experienced in performing work of similar type and scope.

B.  Unless approved by the Architect, provide all related products and accessories from one manufacturer.

C.  Ventilated rainscreen system shall provide complete secondary drainage system, draining at base of wall.  Supporting substrate for exterior wall panels shall comply with all current codes and regulations.

1.3       SUBMITTALS

A.  Submit the following within 30 calendar days after receiving the Notice to Proceed.

*Note to specifier:  Submittals are usually required within a specified number of calendar days after the Contractor is given the Notice to Proceed.  30 calendar days is a common requirement for medium- to large-size projects.  Your choice of time will depend on the size of the project and the Owner's need for an expedited schedule.

B.  Submit list of materials to be provided for this work; manufacturer's data required to prove compliance with these Specifications, manufacturer's installation instructions;  shop drawings of the ventilated rainscreen system, as required, with complete details and assembly instructions.

C.  Submit samples as required for approval by the Architect.

*Note to specifier:  Samples may be requested with a different time limit than other submittals.  Details of the samples requested -- sizes, finishes, etc. -- are usually specified.  Delete selection samples if colors have already been selected.

D.  Shop Drawings for Ventilated Rainscreen System: Shop Drawings shall be complete with specific instructions for the installation of panels, sub-frame assemblies and other component parts.  Include engineering analysis.  Drawings shall indicate sizes of ventilation openings and methods of preventing unwanted insects or animals from entering cavity behind panels.

1.4       PRECONSTRUCTION AND PREPARATION

A.  Examine and verify that job conditions are satisfactory for speedy and acceptable work.

B.  Field Measurements: Secure field measurements before preparation of shop drawings and fabrication where possible, for proper fabrication and installation of the work.

C.  Preinstallation Meeting:  Conduct preinstallation meeting to verify project requirements, substrate conditions, manufacturer's installation instructions and manufacturer's warranty requirements.

1.5       DELIVERY, STORAGE, AND HANDLING

A.  Deliver materials in manufacturer's original, unopened, undamaged containers with identification labels intact.  Materials must be transported flat and kept dry and protected from the elements and handled with care.

B.  Storage and Protection:  Materials must be stored flat and kept dry in a warehouse/storage facility, protected from exposure to harmful weather conditions, at temperatures and humidity conditions recommended by the manufacturer.

1.6       PROJECT CONDITIONS

A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results.  Do not install products under environmental conditions outside manufacturer's absolute limits.

1.7       WARRANTY

A.  Project Warranty: Refer to Conditions of the Contract for project warranty provisions.

B.  Manufacturer's Warranty: Submit, for Owner's acceptance, manufacturer's standard warranty document executed by authorized company official.  Manufacturer's warranty is in addition to, and not a limitation of, other rights Owner may have under Contract Documents.

PART 2 PRODUCTS

2.1       MANUFACTURERS

A.  Provide PARKLEX FACADE [Exterior Grade Wood Composite Panels]

Distributed by: Finland Color Plywood Corporation
Corporate Headquarters
1310 Main St.
Venice, CA  90291
Bus: (310) 396-9991
Bus Fax: (310) 396-4482
E-mail: info@fcpcusa.com
Warehouses in Los Angeles, CA & Port Newark, NJ
http://www.fcpcusa.com/

Manufactured by: Composites Gurea, S.A.
Zalain Auzoa 13
31780
Vera de Bidasoa, Navarra
Spain
http://www.parklex.com/

B.  Substitutions: Not Permitted.

2.2       MATERIALS

A.  EXTERIOR GRADE WOOD COMPOSITE PANEL:  Laminated wood panel, double-face, outerply Ayous, or Boak wood coated with phenolic resins; inner core paper fibers treated with thermo-hardened resins.  

1. WOOD VENEER:
GOLD
AMBAR
RUBI
COPPER
ONIX
ANTRA
QUARTZ
Smooth surface (standard). 


* NOTE TO SPECIFIER:  Delete veneers not used on the project.

2. PANEL DIMENSIONS:
1220mm (48") x 2440mm (96") x thickness.
Thickness: 3mm, 6mm, 8mm, 10mm, 12mm and 14mm.


* NOTE TO SPECIFIER:  Delete thicknesses  not used on the project.

3. DIMENSIONAL TOLERANCES:
Length ±2mm, Width ±2mm, Thickness ±0.55mm (10mm thick panel).

4. WEIGHT:
(8mm); 1220mm x 2440mm x 8mm panel weighs approximately 73 pounds.
(10mm); 1220mm x 2440mm x 10mm panel weighs approximately 93 pounds.


* NOTE TO SPECIFIER:  Delete thicknesses  not used on the project.

5. SURFACE BURNING CHARACTERISTICS:
Report on surface burning characteristics determined by ASTM E-84 (twenty-five foot tunnel furnace test method), meets Class B (II) - 75 or under flame spread, with a flame spread index of 40 and smoke developed index of 35. It is possible to manufacture the product to achieve a Class A (Class I) rating - with a flame spread index of 5 and smoke developed index of 10. Please contact us for additional information.


6. THERMAL PROPERTIES:  

 

Parameter Description

Metric

English

Thermal Conductivity k

0.18 W/m·K

0.104 (Btu/h)/ft·F

Thermal Resistance R (10mm)

0.0556 K·m2/W

0.315 h·ft2·F/Btu

Equivalent to R-9.61 (thermal resistance of 1 ft of Parklex insulation, given in h·ft2·F/Btu).

7. TECHNICAL DATA:

Weathering Report Onix
Weathering Report Ambar
Weathering Report Copper
Weathering Report Rubi

 

ASTM Test Results

Characteristics

Standards and test methods

Values


Density (10mm)

ASTM D 2395 Method A

1.51 g/cc

Moisture Content

ASTM D 4442 Method A

2.1%

 

Water Absorption (24 h/23°C)

ASTM D 1037 Method B

0.34% by mass
0.56% by volume

 

Thickness Swelling

 

0.59%

 

Flexural Properties

ASTM D 1037

 

Modulus of Elasticity

 

veneer parallel to long dimension

dry
soaked

19.0 GPa (2,756,000 psi)
18.0 GPa (2,611,000 psi)

veneer perpendicular to long dim.

dry
soaked

  9.0 GPa (1,305,000 psi)
  8.7 GPa (1,261,000 psi)

Bending Strength (MOR)

 

parallel to long direction

dry
soaked

193 MPa (28,000 psi)
200 MPa (29,000 psi)

perpendicular to long direction

dry
soaked

93 MPa (13,500 psi)
108 MPa (15,700 psi)

 

Bond Durability

APA PS-1 6.1.5

 

maximum load

reference
vacuum/pressure soaked
boiled (2 cycles)

2.58 kN (580 lb-f)
3.47 kN (780 lb-f)
2.68 kN (600 lb-f)

Surface Burning Characteristics

ASTM E-84

Class B (II) / Class A (I)

 

Click on the following link for Interpretation of ASTM Test Data on Parklex Facade.


ASTM Testing Performed at AEWC Advanced Engineered Wood Composites Center, University of Maine; ASTM E-84 Testing (Surface Burning) performed at Hardwood Plywood & Veneer Association Laboratory, Reston Virginia.

8. EUROPEAN TEST RESULTS:

 

Characteristics

Standards and test methods

Values

Visible Density

UNE 53.020 (NF T 51-005)

1.4 gr/cc (> 1400 daN/m3 ±50)

Water Absorption

24 h/23°C

<1.5% in mass

Moisture Content

---

<1%

Formaldehyde Content

UNE-EN 312-1:1.997

Class 1 (<1 mg/100g)
(9 ppm - parts per million)

 

Bending Strength
   lengthways
   crosswise


ISO 178


190 MPa
95 MPa

Stretch Modulus
   lengthways
   crosswise


ISO 178


>18,000 MPa
>7,800 MPa

Traction Shearing

NF EN 314-1
1) 2x4 h in boiling water
2) 72 h in boiling water


ShearingR N/mm2/80% adhesion
ShearingR N/mm2/70% adhesion

Compression Strength

ISO 604

220 MPa

External Glueing Quality

EN 311
72 h boiling water

surface tearing <4MPa

Toughness

UNE 56.534/77

16.8

Resistance to Abrasion

UNE 23-727/90 (EN 438)

1,200/13,000 cycles (7,000)

Resistance to Stains

EN 438

5

Resistance to
Cigarette Burns

EN 438

2

Fire Reaction

UNE 23-727/90

Class M2/M1

Fume Toxicity/Opacity

---

Class F1

2.3       FABRICATION

A.  Fabricate composite panels and accessory items in accordance with manufacturer's recommendations and approved submittals.

B.  Fabricate panels to sizes indicated.

PART 3 EXECUTION

3.1       INSPECTION

A.  Examine alignment of backup structure prior to installing sub-frame. Do not proceed until all defects are corrected.

3.2       INSTALLATION

A.  Comply with Manufacturer’s “General Guidelines for Panel Installation” available at http://www.fcpcusa.com.

B.  Install solid exterior wall panels plumb and level and accurately spaced in accordance with manufacturer's recommendations and approved submittals.

C.  Fasten solid exterior wall panels to supporting substrate with fasteners [and adhesive] approved for use with adjoining construction.

D.  Interface with Other Work:


* NOTE TO SPECIFIER:  Include adjacent surfaces to which panels must adjoin.
            1. [Specify applicable requirements for interface with other work.].

E.  Accessory Items: Install corner profiles, gaskets and trim [Insert accessory items.] with fasteners and adhesive appropriate for use with adjoining construction as indicated on drawings and as recommended by manufacturer.

3.3       DAMAGED MATERIAL

A.  Repair or replace all damaged material to the satisfaction of the Architect.

3.4       CLEANING

A.  Do not use abrasive cleaners or cleaning tools.  Dry wipe down panel sections as work progresses.

B.  Provide final cleaning of the wall system.

3.5       PROTECTION

A.  Protect installed product and finish surfaces from damage during construction.

 

END OF SECTION