SECTION 07430
PARKLEX 1000
EXTERIOR GRADE WOOD COMPOSITE PANEL
* NOTE TO SPECIFIER:
Distributed by:
Finland Color Plywood Corporation
Corporate Headquarters
1310 Main St.
Venice, CA 90291
Bus: (310) 396-9991
Bus Fax: (310) 396-4482
E-mail: info@fcpcusa.com
Warehouses in Los Angeles, CA & Port Newark, NJ
http://www.fcpcusa.com/
Manufactured by:
Composites Gurea, S.A.
Zalain Auzoa 13
31780
Vera de Bidasoa, Navarra
Spain
http://www.parklex.com/
PARKLEX 1000 is a prefinished exterior grade wood composite
panel. This HIGH QUALITY panel system has been treated with durable THERMO-HARDENED
resins and has a bakelite core. The panel is dimensionally stable and
is suitable for exterior applications. Minimum maintenance is required;
clean with water and non-abrasive cleaner. PARKLEX 1000 is highly resistant
to varying climatic conditions, including freeze/thaw, salt spray, dry
climate and UV ray exposure. It is non-toxic and resists mold, mildew,
fungus and is impervious to termite. Parklex Facade In 2003, improvements
to the Parklex Facade were put into production. The improvements increase
the age resistance and dimensional stability of the panel. An additional
layer of clear film, developed by the scientists at Parklex, greatly increase
the UV resistance and color stability of the face veneer. Additionally,
the surface gloss of the finish is retained, showing no sign of change
during artificial ageing testing. The improvements also add increased
protection against humidity absorption, increasing the dimensional stability
of the panel.
PART 1 - GENERAL
1.1 WORK
A. Provide everything required to complete the work as
shown on the Drawings and specified herein.
1.2 QUALITY
STANDARDS
A. Provide experienced, well-trained workers competent
to complete the work as specified. Fabricator/installer
shall be experienced in performing work of similar type
and scope.
B. Unless approved by the Architect, provide all related
products and accessories from one manufacturer.
C. Ventilated rainscreen system shall provide complete
secondary drainage system, draining at base of wall. Supporting
substrate for exterior wall panels shall comply with all
current codes and regulations.
1.3
SUBMITTALS
A. Submit the following within 30 calendar days after receiving
the Notice to Proceed.
*Note to specifier: Submittals are usually required within
a specified number of calendar days after the Contractor
is given the Notice to Proceed. 30 calendar days is a common
requirement for medium-
to large-size projects. Your choice of time will depend
on the size of the project and the Owner's need for an
expedited schedule.
B. Submit list of materials to be provided for this work;
manufacturer's data required to prove compliance with these
Specifications, manufacturer's installation instructions;
shop drawings of the ventilated
rainscreen system, as required, with complete details and
assembly instructions.
C. Submit samples as required for approval by the Architect.
*Note to specifier: Samples may be requested with a different
time limit than other submittals. Details of the samples
requested -- sizes, finishes, etc. -- are usually specified.
Delete selection samples
if colors have already been selected.
D. Shop Drawings for Ventilated Rainscreen System: Shop
Drawings shall be complete with specific instructions for
the installation of panels, sub-frame assemblies and other
component parts. Include engineering
analysis. Drawings shall indicate sizes of ventilation
openings and methods of preventing unwanted insects or
animals from entering cavity behind
panels.
1.4 PRECONSTRUCTION AND PREPARATION
A. Examine and verify that job conditions are satisfactory
for speedy and acceptable work.
B. Field Measurements: Secure field measurements before
preparation of shop drawings and fabrication where possible,
for proper fabrication and installation of the work.
C. Preinstallation Meeting: Conduct preinstallation meeting
to verify project requirements, substrate conditions, manufacturer's
installation instructions and manufacturer's warranty requirements.
1.5
DELIVERY, STORAGE,
AND HANDLING
A. Deliver materials in manufacturer's original, unopened,
undamaged containers with identification labels intact.
Materials must be transported flat and kept dry and protected
from the elements and handled
with care.
B. Storage and Protection: Materials must be stored flat
and kept dry in a warehouse/storage facility, protected
from exposure to harmful weather conditions, at temperatures
and humidity conditions
recommended by the manufacturer.
1.6 PROJECT CONDITIONS
A. Maintain environmental conditions (temperature, humidity,
and ventilation) within limits recommended by manufacturer
for optimum results. Do not install products under environmental
conditions outside
manufacturer's absolute limits.
1.7 WARRANTY
A. Project Warranty: Refer to Conditions of the Contract
for project warranty provisions.
B. Manufacturer's Warranty: Submit, for Owner's acceptance,
manufacturer's standard warranty document executed by authorized
company official. Manufacturer's warranty is in addition
to, and not a limitation
of, other rights Owner may have under Contract Documents.
PART
2 PRODUCTS
2.1 MANUFACTURERS
A. Provide PARKLEX 1000 [Exterior Grade Wood Composite
Panels]
Distributed by: Finland Color Plywood Corporation
Corporate Headquarters
1310 Main St.
Venice, CA 90291
Bus: (310) 396-9991
Bus Fax: (310) 396-4482
E-mail: info@fcpcusa.com
Warehouses in Los Angeles, CA & Port Newark, NJ
http://www.fcpcusa.com/
Manufactured by: Composites Gurea, S.A.
Zalain Auzoa 13
31780
Vera de Bidasoa, Navarra
Spain
http://www.parklex.com/
B. Substitutions: Not Permitted.
2.2 MATERIALS
A. EXTERIOR GRADE WOOD COMPOSITE PANEL: Laminated wood
panel, double-face, outerply Eyong, Ayous, or Boak wood
coated with phenolic resins; inner core paper fibers treated
with thermo-hardened resins.
1. WOOD VENEER:
ENP - Eyong Natural
EBP Lt. - Eyong Light Brown
EBP Dk. - Eyong Dark Brown
ANP – Ayous Natural
ABP Lt. – Ayous Light Brown
ABP Dk. – Ayous Dark Brown
BNP – Boak Natural
BBP – Boak Brown
Smooth surface (standard). Grooved surface (special order).
* NOTE TO SPECIFIER: Delete veneers not used on the project.
2. PANEL DIMENSIONS:
1220mm (48") x 2440mm (96") x thickness.
Thickness: 4mm, 6mm, 8mm, 10mm, 13mm and 15mm.
* NOTE TO SPECIFIER: Delete thicknesses not used on the
project.
3. DIMENSIONAL TOLERANCES:
Length ±2mm, Width ±2mm, Thickness ±0.55mm (10mm
thick panel).
4. WEIGHT:
2.23 lb/ft2 (8mm); 1220mm x 2440mm x 8mm panel weighs approximately
72 pounds.
2.8 lb/ft2 (10mm); 1220mm x 2440mm x 10mm panel weighs
approximately 90 pounds.
* NOTE TO SPECIFIER: Delete thicknesses not used on the
project.
5. SURFACE BURNING CHARACTERISTICS:
Report on surface burning characteristics determined by
ASTM E-84 (twenty-five foot tunnel furnace test method),
meets Class B (II) - 75 or under flame spread, with a flame
spread index of 40 and smoke
developed index of 35. It is possible to manufacture the
product to achieve a Class A (Class I) rating - with a
flame spread index of 5 and smoke
developed index of 10. Please contact us for additional
information.
6. THERMAL PROPERTIES
Parameter Description
 |
Metric
 |
English
 |
|
| Thermal Conductivity k |
0.18 W/m·K |
0.104 (Btu/h)/ft·F |
| Thermal Resistance R (10mm) |
0.0556 K·m2/W |
0.315 h·ft2·F/Btu |
| Equivalent to R-9.61 (thermal resistance of 1 ft of Parklex insulation, given in h·ft2·F/Btu). |
7. TECHNICAL DATA
| ASTM Test Results |
| Characteristics |
Standards and test methods |
Values |
|
| Density (10mm) |
ASTM D 2395 Method A |
1.51 g/cc |
| Moisture Content |
ASTM D 4442 Method A |
2.1% |
| |
| Water Absorption (24 h/23°C) |
ASTM D 1037 Method B |
0.34% by mass 0.56% by volume |
| |
| Thickness Swelling |
|
0.59% |
| |
| Flexural Properties |
ASTM D 1037 |
|
| Modulus of Elasticity |
|
| veneer parallel to long dimension |
dry
soaked |
19.0 GPa (2,756,000 psi)
18.0 GPa (2,611,000 psi) |
| veneer perpendicular to long dim. |
dry
soaked |
9.0 GPa (1,305,000 psi)
8.7 GPa (1,261,000 psi) |
| Bending Strength (MOR) |
|
| parallel to long direction |
dry
soaked |
193 MPa (28,000 psi)
200 MPa (29,000 psi) |
| perpendicular to long direction |
dry
soaked |
93 MPa (13,500 psi)
108 MPa (15,700 psi) |
| |
| Bond Durability |
APA PS-1 6.1.5 |
|
| maximum load |
reference
vacuum/pressure soaked
boiled (2 cycles) |
2.58 kN (580 lb-f)
3.47 kN (780 lb-f)
2.68 kN (600 lb-f) |
| Surface Burning Characteristics |
ASTM E-84 |
Class B (II) / Class A (I) |
| |
| Click on the following link for Interpretation of ASTM Test Data on Parklex Facade. |
 ASTM Testing Performed at AEWC Advanced Engineered Wood Composites Center, University of Maine; ASTM E-84 Testing (Surface Burning) performed at Hardwood Plywood & Veneer Association Laboratory, Reston Virginia. |
8. EUROPEAN TEST RESULTS
| Characteristics |
Standards and test methods |
Values |
|
| Visible Density |
UNE 53.020 (NF T 51-005) |
1.4 gr/cc (> 1400 daN/m3
±50) |
| Water Absorption |
24 h/23°C |
<1.5% in mass |
| Moisture Content |
--- |
<1% |
| Formaldehyde Content |
UNE-EN 312-1:1.997 |
Class 1 (<1 mg/100g) (9 ppm - parts per million) |
| |
Bending Strength lengthways
crosswise |
ISO 178 |
190 MPa
95 MPa |
Stretch Modulus lengthways
crosswise |
ISO 178 |
>18,000 MPa >7,800 MPa |
| Traction Shearing |
NF EN 314-1
1) 2x4 h in boiling water
2) 72 h in boiling water |
ShearingR N/mm2/80% adhesion
ShearingR N/mm2/70% adhesion |
| Compression Strength |
ISO 604 |
220 MPa |
| External Glueing Quality |
EN 311
72 h boiling water |
surface tearing <4MPa |
| Toughness |
UNE 56.534/77 |
16.8 |
| Resistance to Abrasion |
UNE 23-727/90 (EN 438) |
1,200/13,000 cycles (7,000) |
| Resistance to Stains |
EN 438 |
5 |
Resistance to
Cigarette Burns |
EN 438 |
2 |
| Fire Reaction |
UNE 23-727/90 |
Class M2/M1 |
| Fume Toxicity/Opacity |
--- |
Class F1 |
2.3 FABRICATION
A. Fabricate composite panels and accessory items in accordance
with manufacturer's recommendations and approved submittals.
B. Fabricate panels to sizes indicated.
PART 3 EXECUTION
3.1
INSPECTION
A. Examine alignment of backup structure prior to installing
sub-frame. Do not proceed until all defects are corrected.
3.2
INSTALLATION
A. Comply with Manufacturer’s “General Guidelines
for Panel Installation” available here.
B. Install solid exterior wall panels plumb and level and
accurately spaced in accordance with manufacturer's recommendations
and approved submittals.
C. Fasten solid exterior wall panels to supporting substrate
with fasteners [and adhesive] approved for use with adjoining
construction.
D. Interface with Other Work:
* NOTE TO SPECIFIER: Include adjacent surfaces to which
panels must adjoin.
1. [Specify applicable requirements for interface with
other work.].
E. Accessory Items: Install corner profiles, gaskets and
trim [Insert accessory items.] with fasteners and adhesive
appropriate for use with adjoining construction
as indicated on drawings and as recommended by manufacturer.
3.3 DAMAGED MATERIAL
A. Repair or replace all damaged material to the satisfaction
of the Architect.
3.4 CLEANING
A. Do not use abrasive cleaners or cleaning tools. Dry
wipe down panel sections as work progresses.
B. Provide final cleaning of the wall system.
3.5 PROTECTION
A. Protect installed product and finish surfaces from
damage during construction.
END OF SECTION |